- 【必看!】變壓器經典問答五十道&史上最全干式變壓器暢銷榜
- 發布人:電小老虎網 時間:2016-05-06 新聞來源:電虎網 瀏覽量:
1、油浸變壓器有哪些主要部件?
答:變壓(ya)器(qi)的(de)主要(yao)部件有(you):鐵芯(xin)、繞組、油箱、油枕(zhen)、呼(hu)吸器(qi)、防爆管(guan)、散(san)熱器(qi)、絕緣套(tao)管(guan)、分接開關、氣體繼電器(qi)、溫(wen)度計、凈(jing)油等。
2、什么叫全絕緣變壓器?什么叫半絕緣變壓器?
答(da):半絕(jue)(jue)(jue)緣(yuan)(yuan)就是變壓器的(de)(de)*近中(zhong)性點部分繞組(zu)的(de)(de)主絕(jue)(jue)(jue)緣(yuan)(yuan),其絕(jue)(jue)(jue)緣(yuan)(yuan)水(shui)平比端(duan)部繞組(zu)的(de)(de)絕(jue)(jue)(jue)緣(yuan)(yuan)水(shui)平低,而與此相反(fan),一般(ban)變壓器首端(duan)與尾(wei)端(duan)繞組(zu)絕(jue)(jue)(jue)緣(yuan)(yuan)水(shui)平一樣(yang)叫全絕(jue)(jue)(jue)緣(yuan)(yuan)。
3、變壓器在電力系統中的主要作用是什么?
答(da):變(bian)壓(ya)器中電(dian)(dian)力(li)系統中的作(zuo)用是變(bian)換電(dian)(dian)壓(ya),以利于(yu)功率的傳(chuan)輸。電(dian)(dian)壓(ya)經(jing)升(sheng)壓(ya)變(bian)壓(ya)器升(sheng)壓(ya)后,可以減少線路(lu)損耗,提(ti)高送電(dian)(dian)的經(jing)濟性,達到遠(yuan)距離送電(dian)(dian)的目的。而降壓(ya)變(bian)壓(ya)器則能把高電(dian)(dian)壓(ya)變(bian)為用戶所需(xu)(xu)要(yao)(yao)的各級使(shi)用電(dian)(dian)壓(ya),滿足用戶需(xu)(xu)要(yao)(yao)。
4、套管裂紋有什么危害性?
答(da):套管(guan)出現(xian)裂紋會使絕(jue)緣強度降低,能造成絕(jue)緣的(de)(de)進(jin)一步(bu)損壞,直至全(quan)部擊穿。裂縫(feng)中的(de)(de)水結(jie)冰時也可能將套管(guan)脹裂。可見套管(guan)裂紋對變壓器的(de)(de)安全(quan)運(yun)行是很有威脅的(de)(de)。
5、中性點與零點、零線有何區別?
答:凡三相(xiang)繞組的(de)首(shou)端(或(huo)尾端)連(lian)(lian)接(jie)在一起的(de)共(gong)同連(lian)(lian)接(jie)點(dian),稱(cheng)電源中(zhong)性點(dian)。當(dang)電源的(de)中(zhong)性點(dian)與(yu)接(jie)地裝置有良好的(de)連(lian)(lian)接(jie)時,該中(zhong)性點(dian)便稱(cheng)為(wei)零(ling)點(dian);而由零(ling)點(dian)引出(chu)的(de)導線,則稱(cheng)為(wei)零(ling)線。
6、為什么室外母線接頭易發熱?
答:室外母線要(yao)經常受到風(feng)、雨、雪、日曬、冰凍(dong)等(deng)侵(qin)蝕(shi)。這些都可(ke)促使母線接(jie)頭加速氧化、腐蝕(shi),使得接(jie)頭的接(jie)觸電阻增(zeng)大,溫(wen)度升高。
7、SF6氣體有哪些化學性質?
答:SF6氣體(ti)(ti)不溶于水和變壓器(qi)油,在熾熱的(de)(de)(de)溫度下,它與(yu)氧氣、氬氣、鋁及其他許多(duo)物(wu)質不發生作(zuo)用。但在電(dian)弧和電(dian)暈的(de)(de)(de)作(zuo)用下,SF6氣體(ti)(ti)會(hui)分解,產(chan)生低氟化(hua)合(he)物(wu),這些化(hua)合(he)物(wu)會(hui)引起絕緣材料的(de)(de)(de)損壞,且這些低氟化(hua)合(he)物(wu)是劇毒(du)氣體(ti)(ti)。SF6的(de)(de)(de)分解反應(ying)與(yu)水分有很大關系(xi),因(yin)此要有去潮措(cuo)施。
8、變壓器的油枕起什么作用?
答:當變壓器油(you)(you)的(de)(de)體積隨著油(you)(you)溫的(de)(de)變化(hua)而(er)膨脹或縮小時,油(you)(you)枕(zhen)起儲油(you)(you)和(he)補油(you)(you)作用(yong),能保(bao)證油(you)(you)箱內充滿油(you)(you),同時由于裝(zhuang)了油(you)(you)枕(zhen),使變壓器與空(kong)氣的(de)(de)接觸面減小,減緩(huan)了油(you)(you)的(de)(de)劣化(hua)速度。油(you)(you)枕(zhen)的(de)(de)側面還裝(zhuang)有油(you)(you)位(wei)計(ji),可以監視油(you)(you)位(wei)的(de)(de)變化(hua)。
9、變壓器的鐵芯為什么要接地?
答(da):運行中變(bian)(bian)壓(ya)(ya)(ya)器的(de)鐵(tie)芯及其他附(fu)件都(dou)處(chu)于繞組周圍的(de)電場(chang)內,如不接地(di),鐵(tie)芯及其他附(fu)件必然感應(ying)一(yi)定的(de)電壓(ya)(ya)(ya),在外加電壓(ya)(ya)(ya)的(de)作(zuo)用下,當感應(ying)電壓(ya)(ya)(ya)超過對(dui)地(di)放(fang)電電壓(ya)(ya)(ya)時,就(jiu)會產生放(fang)電現象。為了避(bi)免變(bian)(bian)壓(ya)(ya)(ya)器的(de)內部(bu)放(fang)電,所以要(yao)將(jiang)鐵(tie)芯接地(di)。
10、為什么要在電力電容器與其斷路器之間裝設一組ZnO避雷器?
答:裝(zhuang)設ZnO避雷器(qi)(qi)可(ke)以防止電(dian)力電(dian)容器(qi)(qi)在拉、合操(cao)(cao)作(zuo)時可(ke)能出(chu)現的操(cao)(cao)作(zuo)過電(dian)壓,保證電(dian)氣設備的安全運(yun)行。
11、電能表和功率表指示的數值有哪些不同?
答:功(gong)(gong)率表指示的(de)(de)是瞬時的(de)(de)發、供、用電(dian)設備所發出、傳送和消耗的(de)(de)電(dian)功(gong)(gong)數(shu);而電(dian)能表的(de)(de)數(shu)值是累(lei)計某一(yi)段(duan)時間內(nei)所發出、傳送和消耗的(de)(de)電(dian)能數(shu)。
12、對并聯電池組的電池有什么要求?
答:并聯電(dian)(dian)(dian)(dian)(dian)池(chi)中(zhong)各(ge)電(dian)(dian)(dian)(dian)(dian)池(chi)的(de)電(dian)(dian)(dian)(dian)(dian)動勢(shi)要相等(deng),否則電(dian)(dian)(dian)(dian)(dian)動勢(shi)大(da)的(de)電(dian)(dian)(dian)(dian)(dian)池(chi)會對電(dian)(dian)(dian)(dian)(dian)動勢(shi)小(xiao)的(de)電(dian)(dian)(dian)(dian)(dian)池(chi)放電(dian)(dian)(dian)(dian)(dian),在電(dian)(dian)(dian)(dian)(dian)池(chi)組內(nei)部形成環流(liu)。另外,各(ge)個電(dian)(dian)(dian)(dian)(dian)池(chi)的(de)內(nei)阻也應相同(tong),否則內(nei)阻小(xiao)的(de)電(dian)(dian)(dian)(dian)(dian)池(chi)的(de)放電(dian)(dian)(dian)(dian)(dian)電(dian)(dian)(dian)(dian)(dian)流(liu)會過大(da)。新舊程(cheng)度不(bu)同(tong)的(de)電(dian)(dian)(dian)(dian)(dian)池(chi)不(bu)宜并聯使(shi)用。
13、中央信號裝置有什么作用?
答:中央(yang)信號是監(jian)視變(bian)電(dian)(dian)站(zhan)電(dian)(dian)氣設(she)(she)備運行的一(yi)種信號裝(zhuang)置,根(gen)據電(dian)(dian)氣設(she)(she)備的故障特點發出(chu)音響(xiang)和(he)燈光信號,告(gao)知(zhi)運行人員迅速(su)查找,作出(chu)正確(que)判(pan)斷(duan)和(he)處理,保證設(she)(she)備的安全運行。
14、為什么電纜線路停電后用驗電筆驗電時,短時間內還有電?
答(da):電(dian)(dian)(dian)(dian)纜線(xian)路相(xiang)當于一個電(dian)(dian)(dian)(dian)容器,停電(dian)(dian)(dian)(dian)后(hou)線(xian)路還存(cun)有剩余電(dian)(dian)(dian)(dian)荷,對地仍然(ran)有電(dian)(dian)(dian)(dian)位差。若停電(dian)(dian)(dian)(dian)立(li)即驗(yan)電(dian)(dian)(dian)(dian),驗(yan)電(dian)(dian)(dian)(dian)筆會顯示出(chu)線(xian)路有電(dian)(dian)(dian)(dian)。因此必須經過(guo)充分放電(dian)(dian)(dian)(dian),驗(yan)電(dian)(dian)(dian)(dian)無(wu)電(dian)(dian)(dian)(dian)后(hou),方可裝設接地線(xian)。
15、什么是內部過電壓?
答:內(nei)部(bu)(bu)過(guo)(guo)電(dian)(dian)壓(ya)是(shi)由(you)于操作、事故或其他原(yuan)因引起(qi)系統(tong)的(de)狀態發生突(tu)然(ran)變化將出(chu)現從一(yi)種穩定(ding)狀態轉(zhuan)變為另一(yi)種穩定(ding)狀態的(de)過(guo)(guo)渡過(guo)(guo)程(cheng),在這(zhe)個過(guo)(guo)程(cheng)中可(ke)能(neng)對系統(tong)有(you)危險的(de)過(guo)(guo)電(dian)(dian)壓(ya)。這(zhe)些過(guo)(guo)電(dian)(dian)壓(ya)是(shi)系統(tong)內(nei)電(dian)(dian)磁(ci)能(neng)的(de)振(zhen)蕩和積聚志引起(qi)的(de),所以叫內(nei)部(bu)(bu)過(guo)(guo)電(dian)(dian)壓(ya)。
16、220kV閥型避雷器上部均壓環起什么作用?
答:加裝均壓(ya)環后,使避雷(lei)器電壓(ya)分布均勻(yun)。
17、何謂保護接零?有什么優點?
答:保(bao)護(hu)接零就是將(jiang)設備(bei)在正常(chang)情況下(xia)不帶電的金屬(shu)部(bu)分(fen),用(yong)導線與系統進(jin)行直接相連的方(fang)式。采(cai)取保(bao)護(hu)接零方(fang)式,保(bao)證人身(shen)安全,防止發生(sheng)觸(chu)電事故。
18、高壓斷路器有什么作用?
答:高壓斷路器不僅可(ke)以(yi)切斷和(he)接通正(zheng)常情況下高壓電路中(zhong)的空載(zai)電流和(he)負荷電流,還可(ke)以(yi)在系(xi)統(tong)(tong)發生故(gu)(gu)障時與保(bao)護裝置(zhi)及自動裝置(zhi)相配合(he),迅(xun)速切斷故(gu)(gu)障電流,防(fang)止(zhi)事故(gu)(gu)擴大(da),保(bao)證系(xi)統(tong)(tong)的安(an)全(quan)運行(xing)。
19、直流系統在變電站中起什么作用?
答:直(zhi)流系統(tong)在變(bian)(bian)電(dian)站中為控制(zhi)、信號(hao)、繼電(dian)保護、自(zi)動裝置及事故照(zhao)明等提(ti)供可(ke)*的(de)(de)直(zhi)流電(dian)源(yuan)。它還(huan)為操(cao)作提(ti)供可(ke)*的(de)(de)操(cao)作電(dian)源(yuan)。直(zhi)流系統(tong)的(de)(de)可(ke)*與否(fou),對變(bian)(bian)電(dian)站的(de)(de)安全運行起著至關重(zhong)要的(de)(de)作用,是變(bian)(bian)電(dian)站安全運行的(de)(de)保證。
20、為使蓄電池在正常浮充電時保持滿充電狀態,每個蓄電池的端電壓應保持為多少?
答(da):為了使(shi)蓄電(dian)池(chi)保持在滿(man)充電(dian)狀態,必須使(shi)接向直流母線的每個蓄電(dian)池(chi)在浮(fu)充時保持有2.15V的電(dian)壓。
21、為什么要裝設直流絕緣監視裝置?
答:變電站的(de)直(zhi)流系統(tong)中一(yi)極(ji)接地長期工作是不允許的(de),因為在同(tong)一(yi)極(ji)的(de)另(ling)(ling)一(yi)地點再發生接地時,就可能造成(cheng)信(xin)號裝置、繼(ji)電保護(hu)和控制電路的(de)誤動作。另(ling)(ling)外在有一(yi)極(ji)接地時,假如再發生另(ling)(ling)一(yi)極(ji)接地就將造成(cheng)直(zhi)流短路。
22、說明什么叫浮充電?
答:浮(fu)充(chong)電就(jiu)是(shi)裝設在兩臺(tai)(tai)充(chong)電機組(zu),一(yi)臺(tai)(tai)是(shi)主充(chong)電機組(zu),另一(yi)臺(tai)(tai)是(shi)浮(fu)充(chong)電機組(zu)。浮(fu)充(chong)電是(shi)為了補償電池(chi)的(de)自放電損耗(hao),使蓄電池(chi)組(zu)經常處于完全充(chong)電狀(zhuang)態。
23、阻波器有什么作用?
答:阻波(bo)器是(shi)載(zai)波(bo)通信(xin)及高頻(pin)保護不可缺少的高頻(pin)通信(xin)元件,它阻止高頻(pin)電流向其他(ta)分支泄(xie)漏,起減少高頻(pin)能量損耗的作用。
24、系統發生振蕩時有哪些現象?
答:系統發生振蕩時的現象有:
(1)變電站內的電流、電壓表和功率表的指針呈周期性擺動,如有聯絡線,表計的擺動最明顯。
(2)距系統振(zhen)蕩中(zhong)心越近,電(dian)壓擺動越大,白熾燈忽明(ming)忽暗,非常明(ming)顯。
25、掉牌未復歸信號的作用是什么?
答(da):掉牌未復(fu)歸燈光信號,是為使(shi)值班人員(yuan)在記錄保護動作(zuo)情況的過程中(zhong),不致于發生遺漏(lou)造成誤(wu)判斷(duan),應注意及(ji)時(shi)復(fu)歸信號掉牌,以免出(chu)現重(zhong)復(fu)動作(zuo),使(shi)前后兩次不能區(qu)分(fen)。
26、低壓交直流回路能否共用一條電纜,為什么?
答:不能,因為:
(1)共用一條電纜能降低直流系統的絕緣水平。
(2)如果(guo)直流絕緣破壞(huai),則直流混線會造成短路或(huo)繼電保護誤動等。
27、測二次回路的絕緣應使用多大的兆歐表?絕緣標準是多少兆歐?
答:測二次回(hui)路的絕緣電阻值(zhi)最好是使用(yong)1000V兆(zhao)歐表(biao),如果沒有1000V的也可(ke)用(yong)500V的兆(zhao)歐表(biao)。其絕緣標準:運行中的不(bu)低于(yu)1兆(zhao)歐,新投入的,室內不(bu)低于(yu)20兆(zhao)歐,室外不(bu)低于(yu)10兆(zhao)歐。
28、油開關的輔助觸點有哪些用途?
答:油(you)斷(duan)(duan)(duan)路(lu)(lu)器(qi)本身所帶常(chang)開(kai)、常(chang)閉觸(chu)點(dian)變換開(kai)合位置(zhi)(zhi),來(lai)接通(tong)斷(duan)(duan)(duan)路(lu)(lu)器(qi)機構合閘及跳閘回路(lu)(lu)和(he)音(yin)響(xiang)(xiang)信號回路(lu)(lu),達到斷(duan)(duan)(duan)路(lu)(lu)器(qi)斷(duan)(duan)(duan)開(kai)或閉合電路(lu)(lu)的(de)(de)目的(de)(de),并能正確(que)發出音(yin)響(xiang)(xiang)信號,起(qi)動自(zi)動裝(zhuang)置(zhi)(zhi)和(he)保(bao)護的(de)(de)閉鎖回路(lu)(lu)等。當斷(duan)(duan)(duan)路(lu)(lu)器(qi)的(de)(de)輔助觸(chu)點(dian)用在(zai)合閘及跳閘回路(lu)(lu)時,均(jun)應帶有延時。
29、電流互感器有什么作用?
答:電流互感器把(ba)大電流按一(yi)定比例變為小電流,提(ti)供(gong)各種儀表使用(yong)和(he)繼電保護用(yong)的(de)電流,并將二次系統與高電壓隔離(li)。它不(bu)僅保證了(le)人(ren)身和(he)設備的(de)安全,也使儀表和(he)繼電器的(de)制造簡(jian)單(dan)化(hua)、標準化(hua),提(ti)高了(le)經濟效益。
30、過流保護的動作原理是什么?
答:電(dian)(dian)(dian)(dian)(dian)網中發生相間短路(lu)故障(zhang)時,電(dian)(dian)(dian)(dian)(dian)流會突然增大,電(dian)(dian)(dian)(dian)(dian)壓突然下降,過流保(bao)護就是按線路(lu)選擇性(xing)的(de)要(yao)求(qiu),整定電(dian)(dian)(dian)(dian)(dian)流繼電(dian)(dian)(dian)(dian)(dian)器的(de)動(dong)作(zuo)(zuo)電(dian)(dian)(dian)(dian)(dian)流的(de)。當(dang)線路(lu)中故障(zhang)電(dian)(dian)(dian)(dian)(dian)流達(da)到電(dian)(dian)(dian)(dian)(dian)流繼電(dian)(dian)(dian)(dian)(dian)器的(de)動(dong)作(zuo)(zuo)值時,電(dian)(dian)(dian)(dian)(dian)流繼電(dian)(dian)(dian)(dian)(dian)器動(dong)作(zuo)(zuo)按保(bao)護裝置選擇性(xing)的(de)要(yao)求(qiu),有(you)選擇性(xing)的(de)切斷故障(zhang)線路(lu)。
31、電流互感器有哪幾種接線方式?
答:電(dian)流(liu)互(hu)感器(qi)(qi)的接線方式,有使用(yong)兩(liang)(liang)個電(dian)流(liu)互(hu)感器(qi)(qi)兩(liang)(liang)相V形接線和(he)兩(liang)(liang)相電(dian)流(liu)差接線;有使用(yong)三(san)(san)個電(dian)流(liu)互(hu)感器(qi)(qi)的三(san)(san)相Y形接線、三(san)(san)相Δ形接線和(he)零序接線。
32、電力系統中的無功電源有幾種?
答:電力系統中的無功電源(yuan)有:①同步發電機;②調相機;③并聯補(bu)償電容器;④串聯補(bu)償電容器;⑤靜止補(bu)償器。
33、變壓器的凈油器是根據什么原理工作的?
答:運行中的(de)(de)(de)變壓(ya)器因(yin)上層油(you)(you)(you)(you)溫(wen)與下(xia)層油(you)(you)(you)(you)溫(wen)的(de)(de)(de)溫(wen)差,使油(you)(you)(you)(you)在凈油(you)(you)(you)(you)器內循環(huan)。油(you)(you)(you)(you)中的(de)(de)(de)有害物(wu)質(zhi)如:水分、游離碳(tan)、氧化(hua)物(wu)等隨油(you)(you)(you)(you)的(de)(de)(de)循環(huan)被凈油(you)(you)(you)(you)器內的(de)(de)(de)硅膠吸收,使油(you)(you)(you)(you)凈化(hua)而保持良好的(de)(de)(de)電(dian)氣及化(hua)學性能,起到對變壓(ya)器油(you)(you)(you)(you)再生的(de)(de)(de)作用。
34、有導向與無導向的變壓器強油風冷裝置的冷卻效果如何?
答:裝有無導(dao)(dao)向(xiang)強(qiang)油(you)風冷(leng)(leng)裝置的變(bian)壓器的大部(bu)分油(you)流通(tong)(tong)過箱(xiang)壁和繞(rao)組(zu)(zu)之間(jian)的空隙(xi)流回,少部(bu)分油(you)流進入繞(rao)組(zu)(zu)和鐵(tie)芯內部(bu),其(qi)冷(leng)(leng)卻(que)(que)(que)效(xiao)(xiao)果(guo)不高。而流入有導(dao)(dao)向(xiang)強(qiang)油(you)風冷(leng)(leng)變(bian)壓器油(you)箱(xiang)的冷(leng)(leng)卻(que)(que)(que)油(you)流通(tong)(tong)過油(you)流導(dao)(dao)向(xiang)隔板(ban),有效(xiao)(xiao)地流過鐵(tie)芯和繞(rao)組(zu)(zu)內部(bu),提高了(le)冷(leng)(leng)卻(que)(que)(que)效(xiao)(xiao)果(guo),降低了(le)繞(rao)組(zu)(zu)的溫升。
35、溫度計有什么作用?有幾種測量方法?
答:溫(wen)度計(ji)(ji)是用來(lai)測量油箱里面上(shang)層(ceng)油溫(wen)的,起到監視電(dian)力變(bian)壓器是否(fou)正(zheng)常運(yun)行的作(zuo)用。溫(wen)度計(ji)(ji)按變(bian)壓器容量大(da)小可分為水銀溫(wen)度計(ji)(ji)、信號(hao)溫(wen)度計(ji)(ji)、電(dian)阻溫(wen)度計(ji)(ji)三種測溫(wen)方法。
36、高壓斷路器的分合閘緩沖器起什么作用?
答(da):分閘緩沖器(qi)的作(zuo)(zuo)用(yong)是防(fang)止因彈簧釋放能量時(shi)產生的巨(ju)大沖擊(ji)力損壞(huai)斷(duan)路器(qi)的零部件(jian)。合閘緩沖器(qi)的作(zuo)(zuo)用(yong)是防(fang)止合閘時(shi)的沖擊(ji)力使合閘過(guo)深而損壞(huai)套管。
37、什么叫斷路器自由脫扣?
答:斷路(lu)(lu)(lu)器在合(he)閘過程中(zhong)的任何時刻,若保護動(dong)作接通跳閘回路(lu)(lu)(lu),斷路(lu)(lu)(lu)器能可*地斷開,這就叫自由脫扣(kou)。帶有自由脫扣(kou)的斷路(lu)(lu)(lu)器,可以(yi)保證斷路(lu)(lu)(lu)器合(he)于(yu)短路(lu)(lu)(lu)故障(zhang)時,能迅速斷開,避免擴大事(shi)故范圍(wei)。
38、SF6氣體有哪些良好的滅弧性能?
答:SF6氣體有以下幾點良好的性能:
(1)弧柱導電率高,燃弧電壓很低,弧柱能量較小。
(2)當交流電流過零時,SF6氣體的介質絕緣強度恢復快,約比空氣快100倍,即它的滅弧能力比空氣的高100倍。
(3)SF6氣體的絕(jue)緣強(qiang)度(du)較高。
39、真空斷路器有哪些特點?
答:真空(kong)斷路器(qi)(qi)具(ju)有觸頭開距(ju)小,燃弧時間(jian)短,觸頭在(zai)開斷故障電流時燒傷輕微(wei)等特點,因此真空(kong)斷路器(qi)(qi)所需的操作(zuo)能量(liang)小,動作(zuo)快。它同時還具(ju)有體積小、重(zhong)量(liang)輕、維護工作(zuo)量(liang)小,能防火(huo)、防爆,操作(zuo)噪聲小的優(you)點。
40、同步調相機的同步是什么意思?
答:當調相機運行時,定子的(de)旋轉(zhuan)磁場(chang)和轉(zhuan)子以(yi)相同(tong)的(de)方向、相同(tong)的(de)速度旋轉(zhuan),這就叫做同(tong)步。
41、電壓互感器一次側熔絲熔斷后,為什么不允許用普通熔絲代替?
答:以10kV電壓互感器為例,一(yi)次側熔(rong)斷(duan)器熔(rong)絲的額定電流(liu)是0.5A。采用石(shi)英砂填充的熔(rong)斷(duan)器具(ju)有較好的滅弧性能(neng)和較大的斷(duan)流(liu)容(rong)量,同時具(ju)有限制短路電流(liu)的作用。而普通熔(rong)絲則(ze)不(bu)能(neng)滿足斷(duan)流(liu)容(rong)量要(yao)求(qiu)。
42、為什么電壓互感器和電流互感器的二次側必須接地?
答:電(dian)壓(ya)互(hu)感器和電(dian)流互(hu)感器的二(er)(er)(er)次(ci)(ci)側接(jie)地屬(shu)于保護接(jie)地。因(yin)為一、二(er)(er)(er)次(ci)(ci)側絕(jue)緣(yuan)如果損壞,一次(ci)(ci)側高壓(ya)串到二(er)(er)(er)次(ci)(ci)側,就會威(wei)脅人身和設備的安(an)全(quan),所以二(er)(er)(er)次(ci)(ci)側必須(xu)接(jie)地。
43、FKL-10-2×750-6是什么電氣設備的銘牌?
答:FKL-10-2×750-6是額(e)定電抗為6%,額(e)定電壓為10kV,兩個支路(lu)的(de)額(e)定電流是750A的(de)鋁電纜(lan)分裂電抗器的(de)銘牌。
44、并聯電抗器和串聯電抗器各有什么作用?
答:線(xian)路(lu)并聯電(dian)(dian)(dian)抗器(qi)可以補償(chang)線(xian)路(lu)的(de)容性充電(dian)(dian)(dian)電(dian)(dian)(dian)流,限制(zhi)系統(tong)電(dian)(dian)(dian)壓(ya)(ya)(ya)升(sheng)高(gao)(gao)和(he)操(cao)作過電(dian)(dian)(dian)壓(ya)(ya)(ya)的(de)產生(sheng),保證線(xian)路(lu)的(de)可*運行(xing)。母線(xian)串(chuan)聯電(dian)(dian)(dian)抗器(qi)可以限制(zhi)短路(lu)電(dian)(dian)(dian)流,維持母線(xian)有較高(gao)(gao)的(de)殘壓(ya)(ya)(ya)。而電(dian)(dian)(dian)容器(qi)組(zu)串(chuan)聯電(dian)(dian)(dian)抗器(qi)可以限制(zhi)高(gao)(gao)次(ci)諧波,降低電(dian)(dian)(dian)抗。
45、單母線分段的接線方式有什么特點?
答:單母(mu)線(xian)(xian)分(fen)(fen)段(duan)接線(xian)(xian)可以減少母(mu)線(xian)(xian)故(gu)障(zhang)的(de)影響(xiang)范圍(wei)。當一段(duan)母(mu)線(xian)(xian)有故(gu)障(zhang)時,分(fen)(fen)段(duan)斷(duan)路器(qi)在(zai)繼(ji)電(dian)保(bao)護的(de)配合下自動跳閘,切除故(gu)障(zhang)段(duan),使非故(gu)障(zhang)母(mu)線(xian)(xian)保(bao)持(chi)正常供電(dian)。對于重(zhong)要用戶(hu),可以從不同的(de)分(fen)(fen)段(duan)上取得電(dian)源(yuan),保(bao)證不中斷(duan)供電(dian)。
46、雙母線接線存在哪些缺點?
答:雙母線接線存在以下缺點:
(1)接線及操作都比較復雜,倒閘操作時容易發生誤操作。
(2)母(mu)線(xian)隔離開關較多,配電裝置的結構也較復雜,所以經濟性較差。
47、故障錄波器有什么作用?
答:故(gu)障錄波器用于電(dian)力系統,可(ke)在(zai)系統發(fa)生故(gu)障時,自動(dong)地、準確(que)地記錄故(gu)障前、后過(guo)程的(de)(de)各種電(dian)氣量(liang)的(de)(de)變化情況,通(tong)過(guo)這些(xie)電(dian)氣量(liang)的(de)(de)分析、比(bi)較,對分析處理事故(gu)、判斷保(bao)護是否正確(que)動(dong)作、提高(gao)電(dian)力系統安(an)全運行水平均(jun)有著重要作用。
48、為什么硬母線要裝設伸縮接頭?
答:物(wu)體都有熱(re)脹冷(leng)縮(suo)特性,母線在(zai)運行中會(hui)因發熱(re)而(er)使長(chang)度發生變化。為避免因熱(re)脹冷(leng)縮(suo)的(de)變化使母線和支(zhi)持絕緣子受到過大的(de)應(ying)力并損壞,所以應(ying)在(zai)硬(ying)母線上裝設伸(shen)縮(suo)接頭。
49、什么叫消弧線圈的補償度,什么叫殘流?
答(da):消弧線圈(quan)的電(dian)(dian)感(gan)電(dian)(dian)流與電(dian)(dian)容電(dian)(dian)流之差和(he)電(dian)(dian)網的電(dian)(dian)容電(dian)(dian)流之比叫補償度(du)。消弧線圈(quan)的電(dian)(dian)感(gan)電(dian)(dian)流補償電(dian)(dian)容電(dian)(dian)流之后,流經接(jie)地點的剩余(yu)電(dian)(dian)流,叫殘流。
50、中性點經消弧線圈接地的系統正常運行時,消弧線圈是否帶有電壓?
答:系統正常運行時,由于線(xian)路的三(san)相對地電(dian)(dian)容(rong)不平(ping)衡,網絡中性點與地之(zhi)間存在(zai)一定電(dian)(dian)壓(ya),其電(dian)(dian)壓(ya)值(zhi)的大小直(zhi)接與電(dian)(dian)容(rong)的不平(ping)衡度有關。在(zai)正常情況下,中性點所產生(sheng)的電(dian)(dian)壓(ya)不能超(chao)過額定相電(dian)(dian)壓(ya)的1.5%。
世上(shang)最全干試(shi)配(pei)電(dian)變壓器(qi)銷(xiao)量排行榜
序號
|
企業名稱
|
1
|
保定天威集團有限公司
|
2
|
江蘇華鵬變壓器有限公司
|
3
|
新疆特變電工
|
4
|
中電電氣集團有限公司
|
5
|
特變電工沈陽變壓器集團有限公司
|
6
|
杭州錢江電氣集團股份有限公司
|
7
|
山東達馳電氣股份有限公司
|
8
|
重慶ABB變壓器有限公司
|
9
|
華通機電集團有限公司
|
10
|
海南金盤電氣有限公司
|
11
|
云南通變電器有限公司
|
12
|
江西變電設備有限公司
|
13
|
天津特變電工變壓器有限公司
|
14
|
南京立業電力變壓器有限公司
|
15
|
海南威特電氣集團有限公司
|
16
|
南京大全變壓器有限公司
|
17
|
施耐德(蘇州)變壓器有限公司
|
18
|
上海ABB變壓器有限公司
|
19
|
順特電氣設備有限公司
|
20
|
西安西電變壓器有限責任公司
|
21
|
三變科技股份有限公司
|
22
|
寧波天安(集團)股份有限公司
|
23
|
鎮江天力變壓器有限公司
|
非包封干式變壓器
序號
|
企業名稱
|
1
|
杭州錢江電氣集團股份有限公司
|
2
|
新疆特變電工
|
3
|
中電電氣集團有限公司
|
4
|
特變電工沈陽變壓器集團有限公司
|
5
|
江西變電設備有限公司
|
6
|
海南威特電氣集團有限公司
|
7
|
南京大全變壓器有限公司
|
8
|
山東達馳電氣股份有限公司
|
9
|
三變科技股份有限公司
|
10
|
鎮江天力變壓器有限公司
|
11
|
吳江市變壓器廠
|
非晶合金干式變壓器
序號
|
企業名稱
|
1
|
杭州錢江電氣集團股份有限公司
|
2
|
中電電氣集團有限公司
|
3
|
海南金盤電氣有限公司
|
4
|
南京大全變壓器有限公司
|
5
|
德力西電氣
|
6
|
上海置信電氣股份有限公司
|
序號
|
企業名稱
|
1
|
新疆特變電工
|
2
|
中電電氣集團有限公司
|
3
|
特變電工沈陽變壓器集團有限公司
|
4
|
江西變電設備有限公司
|
5
|
南京大全變壓器有限公司
|
6
|
上海ABB變壓器有限公司
|
7
|
廣東海鴻電氣
|
序號
|
企業名稱
|
1
|
江蘇華鵬變壓器有限公司
|
2
|
山東達馳電氣股份有限公司
|
3
|
南京大全變壓器有限公司
|
4
|
鎮江天力變壓器有限公司
|
序號
|
企業名稱
|
1
|
杭州錢江電氣集團股份有限公司
|
2
|
山東達馳電氣股份有限公司
|
3
|
海南金盤電氣有限公司
|
4
|
云南通變電器有限公司
|
5
|
南京大全變壓器有限公司
|
序號
|
企業名稱
|
1
|
鹽城奇林電氣有限公司
|
2
|
南京大全變壓器有限公司
|
3
|
沈陽中變變壓器有限公司
|
4
|
新疆特變電工
|
5
|
特變電工衡陽變壓器有限公司
|
6
|
特變電工沈陽變壓器集團有限公司
|
7
|
海南金盤電氣有限公司
|
-
的(de)關(guan)鍵字:變壓器','暢銷榜(bang)','經典問答